    Published:2018-12-19 

Technology

 

  Well Integrity Diagnostic is important to long term production. To find a leak, normally temperature log, acoustic log, packer plugging and mulit-finger log are deployed. Those technologies are difficult to find gas leak, thread leak and seepage leak. Additionally, they are unable to locate the flow behind casing, source of flow and flow migration. 

EverGreen deploys VIVID full bandwidth acoustic and high resolution temperature log to precisely locate the following leaks and flow in one trip:

Tubing leaks

SSSV/GLV/CIV/Thread leaks

Packer leaks

Production casing leaks

A/B/C annulus flow source, point and migration

  Once the leaks are identified, a combination of ERS/PGS/TIP sealants will be pumped into well to cure those leaks. Those include:

  • Setup a balance sealant plug to cure tubing leaks

  • Pump and squeeze sealant to cure leaks in SSSV/GLV/CIV/Wellhead

  • Gravity fall and crosslink to cure packer leaks

  • Pump & gravity fall or squeeze sealant into annulus to cure annulus SCP